<b id='yy846p'><font date-time='60vie2o'></font></b>
                      Product ImageProduct OverviewKey FeaturesSpecificationsMechanical DrawingOrdering InformationCase StudyDownload
                      SICOM3028GPT
                      28 port layer 2/3 managed rack mountable modular switches
                      Product Overview

                      SICOM3028GPT is a intelligent modular platform which is an All-in-One solution integrating IEEE1588v2, Sync-E, full gigabit, and both layer 2 & Layer 3 availability specifically designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments. SICOM3028GPT supports up to 28 gigabit fiber/copper ports, meets the IEC61850 and IEEE1613 standards. SICOM3028GPT is a 19-inch 1U rack mountable device and supports one 1U slot and six 0.5U slots which offers the maximum flexibility for easy expansion.SICOM3028GPT supports IEEE1588v2 and synchronous Ethernet protocol with hardware time stamping and supports the BC, P2P TC, and E2E TC clock modes, it reaches a timing precision of 100 ns. It supports Power Profile and Telecom Profile, and supports many modules for time synchronous like HSR/PRP, TimeServer, GPS, IRIG-B and TMS-trigger etc. SICOM3028GPT supports many Layer 2 software features such as port, VLAN, multicast, QoS, fast redundant ring and Layer 3 functions such as VRRP, RIP, OSFP, IGMP and PIM. It supports Console, Telnet, Web management and network management software based on SNMP. By expanding the serial server module, the product can provide up to 24 RS232/422/485 serial ports. At present, the product is widely used at the intelligent substation and many other industrial communication systems.

                      Key Features

                      Flexible modular design for easy expansion, supports max 28 gigabit fiber/copper ports.
                      Supports DT-Ring ,DRP, MSTP and VRRP for network redundancy.
                      Supports Layer 3 routing protocols such as RIP and OSPF.
                      Supports IEEE1588v2 and the synchronization precision reaches ±100 ns,  with SW based PTP 1588 and optional HW based PTP 1588.
                      Supports ITU-T.G.8261/G.8262 synchronous Ethernet and the synchronization precision reaches ±50 ns.
                      Supports HSR/PRP module, TimeServer module, GPS module, IRIG-B module, TMS-trigger module, Serial server module.
                      Supports Hot-Swappable Power Supplies.
                      Supports IEC61850 MMS management.
                      Supports cable test.
                      Complies with IEC61850-3 and IEEE1613.
                      KEMA, CE, FCC, EN50155/EN50121, NEMA-TS2.

                      Specifications
                      Software functions
                      Switching function Supports VLAN and PVLAN.
                      Supports port aggregation.
                      Supports flow control.
                      Supports broadcast storm suppression.
                      Redundancy protocol Supports DT-Ring, DT-Ring+, and DT-VLAN and the recovery time<50 ms.
                      Supports DHP and DRP and the recovery time<20 ms.
                      Supports RSTP/MSTP and compatible with STP.
                      Multicast protocol Supports IGMP snooping.
                      Supports GMRP.
                      Supports static multicast.
                      Supports GOOSE over IP tunnel (receiver)(Web interface doesn't support)
                      L3 function (part of sub-models support) Supports ARP proxy
                      Supports RIPv1/v2.
                      Supports OSFPv2.
                      Supports static routing.
                      Supports VRRP.
                      Supports IGMP
                      Supports PIM SM
                      Supports GOOSE over IP tunnel (sender) (Web interface doesn't support)
                      Security Supports IEEE 802.1x.
                      Supports HTTPS/SSL.
                      Supports SSH.
                      Supports SFTP
                      Supports RADIUS.
                      Supports TACACS+.
                      Supports user grading.
                      Supports MAC address binding.
                      Supports port isolate.
                      Service quality management Supports ACL
                      Support 802.1p(CoS),DSCP
                      Supports SP and WRR queuing.
                      Management and maintenance Supports Console, Telnet, and Web management methods.
                      Supports SNMPv1/v2c/v3 and can managed by Kyvision.
                      Supports IEC61850 MMS management.
                      Supports file transfer and software update over FTP and TFTP.
                      Supports the IP/MAC address conflict alarm, power failure alarm, power alarm, temperature alarm, port linkdown alarm, port traffic alarm, CRC and packet lose alarm, CPU alarm, memory alarm, Sfp port rx power alarm, transceiver alarm and ring alarm (Web interface doesn’t support address conflict alarm. Sfp port rx power alarm, transceiver alarm need supported by hardware).
                      Supports port mirroring.
                      Supports cable test.
                      Supports loop detection
                      Supports CRC protection
                      Supports Syslog.
                      Supports RMON
                      Supports LLDP.
                      Supports Link-check.
                      Supports NTP and SNTP.
                      Supports RTC.
                      IP address management Supports Bootp.
                      Supports DHCP server/client.
                      Supports Up to 16 different IP addresses and VLAN for system management
                      Time synchronization (part of sub-models support) Supports PTPv2 (IEEE1588-2008).
                      Supports Power profile (C37.238).
                      Supports Telecom profile (in special version).
                      Supports synchronous Ethernet (ITU-T.G.8261/G.8262).
                      Supports TMS function.
                      Product Specifications
                      Standard IEEE 802.3i (10Base-T)
                      IEEE 802.3u (100Base-T)
                      IEEE 802.3ab (1000Base-T)
                      IEEE 802.3ad (port aggregation)
                      IEEE 802.3z (1000Base-SX/LX)
                      IEEE 802.3x (flow control)
                      IEEE 802.1p (priority)
                      IEEE 802.1Q (VLAN)
                      IEEE 802.1w (RSTP)
                      IEEE 802.1s (MSTP)
                      IEEE 802.1x
                      IEEE1588-2008 (PTPv2)
                      ITU-T.G.8261/G.8262 (synchronous Ethernet)
                      Switch properties Priority queue: 8
                      Number of VLANs: 4K
                      VLAN ID: 1–4093
                      Number of multicast groups: 256
                      Routing table: 8K (L2 chassis do not involve)
                      MAC table: 16K
                      Packet buffer: 12Mbit (SICOM3028GPT-L3F/L3FT/L3G/L3GT), 8Mbit (SICOM3028GPT-L2F/L2FT/L2G/L2GT)
                      Packet forwarding rate: 41.7Mpps (SICOM3028GPT-L2G/L2GT/L3G/L3GT), 9.5Mpps (SICOM3028GPT-L2F/L2FT/L3F/L3FT)
                      Switching delay: < 10 μs
                      Jumbo Frame Size: 10 KB
                      Interface Console port: Mini USB, RJ45
                      Alarm contact: 3-pin 5.08mm-spacing plug-in terminal block, 250 VAC/220 VDC Max, 2 A Max, 10A@1s, 60 W Max
                      Slots for module: 1U: 1, 0.5U: 6
                      LED LED on front panel
                      Alarm LED: Alarm
                      Running LED: Run
                      Ring Role LED: Ring
                      Synchronization finish LED: Lock
                      Power LED: PWR1, PWR2
                      Port LED: Link/ACT
                      Port speed LED: Speed

                      LED on rear panel
                      Port LED: Link/ACT
                      Port speed LED: Speed
                      Power Requirements Power input:
                      24VDC (18-36 VDC)
                      48VDC (36-72 VDC)
                      100-240VAC,50/60Hz;110-220VDC (85-264VAC/77-300VDC)
                      Power terminal: 5-pin 5.08 mm-spacing plug-in terminal block
                      Power consumption: < 40 W
                      Overload protection: Support
                      Reverse connection protection: Support
                      Redundancy protection: Support
                      Hot Swappable: Support
                      Physical Characteristics Housing: Metal
                      Cooling: Natural cooling, fanless
                      Protection Class: IP40
                      Dimensions(W×H×D): 482.6 mm × 44 mm × 359.7 mm
                      Weight: < 10 Kg
                      Mounting: 19 inch 1U rack mounting
                      Environmental limits Operating temperature: -40°C to +85°C
                      Storage temperature: -40°C to +85°C
                      Ambient Relative Humidity: 5% to 95% (non-condensing)
                      Quality assurance MTBF:
                      360000h (SICOM3028GPT-L2F/L2G)
                      359000h (SICOM3028GPT-L2FT/L2GT)
                      371000h (SICOM3028GPT-L3F/L3G)
                      368000h (SICOM3028GPT-L3FT/L3GT)
                      Warranty: 5 years
                      Approvals KEMA: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC
                      CE: All models
                      FCC: All models
                      EN50155/50121: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC
                      NEMA-TS2: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC
                      UL61010 (Pending)
                      Industry standard EMI
                      FCC CFR47 Part 15, EN55022/CISPR22, Class A

                      EMS
                      IEC61000-4-2(ESD) ±8 kV (contact), ±15 kV(air)
                      IEC61000-4-3(RS) 10 V/m (80 MHz-2 GHz)
                      IEC61000-4-4(EFT) Power Port: ±4 kV; Data Port: ±2 kV
                      IEC61000-4-5(Surge) Power Port: ±2 kV/DM, ±4 kV/CM; Data Port: ±2 kV
                      IEC61000-4-6(CS) 3 V (10 kHz-150 kHz); 10 V (150 kHz-80 MHz)
                      IEC61000-4-8 (power frequency magnetic field) 100 A/m(cont.), 1000 A/m(1s-3s)
                      IEC61000-4-9 (pulsed magnetic field) 1000 A/m
                      IEC61000-4-10 (damped oscillation) 100 A/m
                      IEC61000-4-12 (oscillatory wave) 2.5 kV/CM, 1 kV/DM
                      IEC61000-4-16 (common mode conduction) 30 V(cont.), 300 V(1s)

                      Machinery
                      IEC60068-2-6 (vibration)
                      IEC60068-2-27 (shock)
                      IEC60068-2-32 (free fall)

                      Climatic environmental
                      IEC60068-2-1 Cold test
                      IEC60068-2-2 Dry heat test
                      IEC60068-2-14 Change of temperature test
                      IEC60068-2-30 Damp heat cyclic test
                      IEC60068-2-78 Damp heat steady state test
                      Mechanical Drawing

                      Hot-Swappable:

                       

                      Ordering Information

                      Product selection table

                      Sub-model Ethernet Ports L2 function L3 function Time synchronization
                      SICOM3028GPT-L2GT Up to 28 Gigabit ports  
                      SICOM3028GPT-L2G Up to 28 Gigabit ports    
                      SICOM3028GPT-L2FT Up to 4 Gigabit ports and 24 Fast Ethernet ports  
                      SICOM3028GPT-L2F Up to 4 Gigabit ports and 24 Fast Ethernet ports    
                      SICOM3028GPT-L3GT Up to 28 Gigabit ports
                      SICOM3028GPT-L3G Up to 28 Gigabit ports  
                      SICOM3028GPT-L3FT Up to 4 Gigabit ports and 24 Fast Ethernet ports
                      SICOM3028GPT-L3F Up to 4 Gigabit ports and 24 Fast Ethernet ports  

                       

                      Ordering Information

                      Recommended model

                      Product Model SICOM3028GPT-SM-PS1-PS2
                      Code definition Code selection
                      SM: Sub-model L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization
                      L2G-MB: SICOM3028GPT 28G ports L2 Chassis
                      L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization
                      L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis
                      L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization
                      L3G-MB: SICOM3028GPT 28G ports L3 Chassis
                      L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization
                      L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis
                      PS1: power input 1 HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)
                      L1=48VDC(36-72VDC)
                      L3=24VDC(18-36VDC)
                      PS2: power input 2 HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)
                      L1=48VDC(36-72VDC)
                      L3=24VDC(18-36VDC)
                      NA: no redundant power supply
                         
                      Hot-Swappable Chassis SICOM3028GPT-SM
                      SM: Sub-model L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization
                      L2G-MB: SICOM3028GPT 28G ports L2 Chassis
                      L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization
                      L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis
                      L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization
                      L3G-MB: SICOM3028GPT 28G ports L3 Chassis
                      L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization
                      L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis
                      Hot-Swappable Power Module SM6.6-Power-PS
                      PS:  power input
                      HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC), 1U
                      L1=48VDC(36-72VDC), 1U
                      L3=24VDC(18-36VDC), 1U
                         
                      Slot 1: SM6.6-Ports-1U
                      Ports: 4GX=4x1000Base-X, 10/100/1000Base-T(X) SFP port,1U
                      4GX-DDM=4x1000Base-X, 10/100/1000Base-T(X) SFP port, DDM, 1U
                      4GE=4x10/100/1000Base-T(X) RJ45 port, 1U
                      2GX2GE=2x1000Base-X, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 1U
                      Slot2-Slot7: SM6.6-Ports-Connector-0.5U
                      Ports: 4GX=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, 0.5U
                      4GX-DDM=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, DDM, 0.5U
                      4SFP=4x100Base-FX SFP port, 0.5U
                      4SFP-DDM=4x100Base-FX SFP port, DDM, 0.5U
                      4GE=4x10/100/1000Base-T(X) RJ45 port, 0.5U
                      2GX2GE=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 0.5U
                      2GX2S=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, single-mode fiber port, 0.5U
                      2GX2M=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, multi-mode fiber port, 0.5U
                      4S=4x100Base-FX, single-mode fiber port, 0.5U
                      4M=4x100Base-FX, multi-mode fiber port, 0.5U
                      2S2T=2x100Base-FX, single-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U
                      2M2T=2x100Base-FX, multi-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U
                      4T=4x10/100Base-T(X) RJ45 port, 0.5U
                      Connector: 100M fiber port specifications SC05=SC connector, multi-mode, 1310nm, 5km
                      ST05=ST connector, multi-mode, 1310nm, 5km
                      FC05=FC connector, multi-mode, 1310nm, 5km
                      SC40=SC connector, single-mode, 1310nm, 40km
                      ST40=ST connector, single-mode, 1310nm, 40km
                      FC40=FC connector, single-mode, 1310nm, 40km
                      SC60=SC connector, single-mode, 1310nm, 60km
                      SC80=SC connector, single-mode, 1550nm, 80km
                      Slot2-Slot7: Module
                       

                      SM6.6-HSR/PRP-GE-0.5U HSR/PRP = Redbox module, 2x100/1000Base-T RJ45 port 
                      SM6.6-HSR/PRP-GX-0.5U HSR/PRP = Redbox module, 2x1000Base-X, 100Base-FX SFP port 
                      SM6.6-PTP-BO-0.5U = PTP-to-IRIG-B convertor module, 2 IRIG-B(AC) outputs, 2 IRIG-B(DC) outputs, 1 PPS output
                      SM6.6-GPS-OI-0.5U = GPS clock synchronization module, 1 GPS antenna input, 1 PPS output
                      SM6.6-4D-232/422/485-0.5U = serial port server module, 4 RS232/422/485 serial ports
                      SM6.6-4D-A-4RS232/422/485-0.5U = enhanced serial port server module, 4 RS232/422/485 serial ports, supports flow control and optical/electrical isolation
                      SM6.6-TMS-Trigger-1U = Time Management System trigger module, 1 IRIG-B output, 1 IRIG-B input, 2 channels for signal input, 2 channels for signal output, 1 Console port
                      SM6.6-TimeServer-ST850-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web.
                      SM6.6-TimeServer-ST850-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,SNMP
                      SM6.6-TimeServer-ST850-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104
                      SM6.6-TimeServer-ST850-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104
                      SM6.6-TimeServer-ST850-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104
                      SM6.6-TimeServer-ST1310-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web
                      SM6.6-TimeServer-ST1310-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web ,SNMP
                      SM6.6-TimeServer-ST1310-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104
                      SM6.6-TimeServer-ST1310-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104
                      SM6.6-TimeServer-ST1310-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104

                       

                      Module adaptive table

                        SICOM3028GPT
                        L2GT L2G L2FT L2F L3GT L3G L3FT L3F
                      SM6.6-HSR/PRP-GE-0.5U
                      SM6.6-HSR/PRP-GX-0.5U
                      SM6.6-PTP-BO-0.5U        
                      SM6.6-GPS-OI-0.5U        
                      SM6.6-TMS-Trigger-1U        
                      SM6.6-TimeServer-ST850-1U        
                      SM6.6-TimeServer-ST850-1U-S1        
                      SM6.6-TimeServer-ST850-1U-S2        
                      SM6.6-TimeServer-ST850-1U-S3        
                      SM6.6-TimeServer-ST850-1U-S4        
                      SM6.6-TimeServer-ST1310-1U        
                      SM6.6-TimeServer-ST1310-1U-S1        
                      SM6.6-TimeServer-ST1310-1U-S2        
                      SM6.6-TimeServer-ST1310-1U-S3        
                      SM6.6-TimeServer-ST1310-1U-S4        
                      SM6.6-4D-232/422/485-0.5U
                      SM6.6-4D-A-4RS232/422/485-0.5U
                      SM6.6-4GX-1U
                      SM6.6-4GX-DDM-1U
                      SM6.6-4GE-1U
                      SM6.6-2GX2GE-1U
                      SM6.6-4GX-0.5U        
                      SM6.6-4GX-DDM-0.5U        
                      SM6.6-4SFP-0.5U        
                      SM6.6-4SFP-DDM-0.5U        
                      SM6.6-4GE-0.5U        
                      SM6.6-2GX2GE-0.5U        
                      SM6.6-2GX2M-ST05-0.5U        
                      SM6.6-2GX2M-SC05-0.5U        
                      SM6.6-2GX2M-FC05-0.5U        
                      SM6.6-2GX2S-ST40-0.5U        
                      SM6.6-2GX2S-SC40-0.5U        
                      SM6.6-2GX2S-FC40-0.5U        
                      SM6.6-2GX2S-SC60-0.5U        
                      SM6.6-2GX2S-SC80-0.5U        
                      SM6.6-4M-ST05-0.5U
                      SM6.6-4M-SC05-0.5U
                      SM6.6-4M-FC05-0.5U
                      SM6.6-4S-ST40-0.5U
                      SM6.6-4S-SC40-0.5U
                      SM6.6-4S-FC40-0.5U
                      SM6.6-4S-SC60-0.5U
                      SM6.6-4S-SC80-0.5U
                      SM6.6-2M2T-ST05-0.5U
                      SM6.6-2M2T-SC05-0.5U
                      SM6.6-2M2T-FC05-0.5U
                      SM6.6-2S2T-ST40-0.5U
                      SM6.6-2S2T-SC40-0.5U
                      SM6.6-2S2T-FC40-0.5U
                      SM6.6-2S2T-SC60-0.5U
                      SM6.6-2S2T-SC80-0.5U v
                      SM6.6-4T-0.5U

                       

                      Accessories

                      Accessory Model Description
                      Gigabit SFP module See the selection table of industrial gigabit SFP module
                      100M SFP module See the selection table of industrial 100M SFP module
                      DT-FCZ-RJ45-01 Single-port RJ45 dust plug
                      DT-XL- Mini USB-USB-2m 2m USB console cable
                      DT-ZJQ-BNC-TNC-01 BNC(female) to TNC(female) connector
                      DT-XL-LMR400-TNC-BNC-20m 20m coaxial cable with BNC(male) to TNC(male) adaptor
                      DT-XL-LMR400-TNC-BNC-2m 2m coaxial cable with BNC(male) to TNC(male) adaptor
                      DT-GPS-ANT-01 GPS antenna, 5 V DC power supply, 1 TNC connector(female)
                      DT-SP-01 GPS surge protection, TNC connector(male) – TNC connector(female)

                       

                      Case Study
                      Download